Ubiquiti EAH-8 | EdgeAccess Hub 8 – Default Title

Ubiquiti EAH-8 | EdgeAccess Hub 8

$2,097.00

Ubiquiti EAH-8 | EdgeAccess Hub 8

$2,097.00

A wall-mounted access control hub for buildings that need centralised management of up to eight doors from a single hardwired panel.

Why this one

  • Eight PoE+ outputs at 30W per port mean readers, intercoms and door controllers all draw power and data from the one panel — no separate PoE injectors scattered across the building.
  • Built-in battery backup support keeps all eight doors operational during a mains outage, which matters anywhere access control is a safety or compliance requirement.
  • Support for up to 10,000 users means it scales from a small office to a large commercial tenancy without needing a second hub or a tier upgrade.
  • Four AUX dry-contact terminals let you wire in chimes, sirens or automatic door openers alongside the eight lock outputs, reducing the need for separate relay hardware.

Good fit if you're fitting out a commercial building, campus or facility with four to eight controlled doors and want a single managed panel that handles power, locking, readers and sensors under UniFi Access.

Worth considering something else if you're controlling fewer than four doors — the UA-G3-SK or UA-G3-SK-PRO starter kits cover smaller deployments without committing to a full panel install, and the EAH-8 is indoor-rated only, so any outdoor enclosure requirement needs separate planning.

What you'll also need

UniFi Access readers (UA-G3 or UA-G3-PRO at each door), a compatible door lock per opening, a UniFi gateway or Cloud Gateway running UniFi Access, and Cat5e or better to each reader and lock position — cable runs up to 100m for electric locks on 18 AWG.

Technical specifications

Overview

Dimensions 379 x 355 x 105 mm
(15 x 14 x 4.1")
Supported Doors 8
Maximum User Count 10,000
Input Terminals (8) Door exit request
(8) Door position
(1) Emergency
Power Method Universal input, 100–240V AC, Max. 4.4A, 50/60 Hz
32–48V DC Lead Acid Battery, Max. 7.5A @32V
UL 294 Level Destructive attack: Level I
Line security: Level I
Endurance: Level I
Standby power: Level I

Mechanical

Weight Device: 9.1 kg (20 lb)
Mount: 624 g (1.4 lb)
Enclosure Material SGCC steel housing with polycarbonate cover
Mount Material SGCC steel
Mounting Wall

Hardware

Digital Input (8) Inputs for request-to-exit devices
(8) Inputs for door position sensors
(1) Emergency
Dry Output Relay (8) Lock terminals (12V or Dry)
(4) AUX terminals for advanced setup (Chime/Siren/Door opener)
Powered Output Relay Lock: 12V DC, 1A/ Dry
Aux: Dry only
Indoor and Outdoor Use Indoor only
Ambient Operating Temperature 0 to 40° C (32 to 104° F)
Ambient Operating Humidity 5 to 95% noncondensing
Networking Interface (10) 10/100/1000 Base-T
PoE Interface (8) PoE+ outputs, 50V DC, 30W per port
(Max 190W aggregated)
Power Supply AC/DC, internal
Max. Power Consumption 240W
Max. PoE Wattage per Port 30W
LEDs W/B <a href="https://help.ui.com/hc/en-us/articles/25738084762775-UniFi-Access-Understand-Access-Device-LED-Status-Indicators" target="_blank" rel="noopener noreferrer">Learn More</a>
Buttons (1) Factory reset
UA-Lock-Electric (400mA) 24 AWG length: 25 m (82 ft)
22 AWG length: 42 m (138 ft)
20 AWG length: 66 m (217 ft)
18 UACC-Cable-DoorLockRelay length: 100 m (328 ft)
UA-Lock-Magnetic-540kg (500mA) 24 AWG length: 20 m (66 ft)
22 AWG length: 32 m (105 ft)
20 AWG length: 51 m (167 ft)
18 UACC-Cable-DoorLockRelay length: 80 m (262 ft)
UA-Lock-Magnetic-270kg (800mA) 24 AWG length: 12 m (39 ft)
22 AWG length: 20 m (66 ft)
20 AWG length: 30 m (98 ft)
18 UACC-Cable-DoorLockRelay length: 46 m (151 ft)
Other locks (1A) 24 AWG length: 9 m (30 ft)
22 AWG length: 15 m (49 ft)
20 AWG length: 24 m (79 ft)
18 UACC-Cable-DoorLockRelay length: 36 m (118 ft)
PoE Cabling Requirements Cable 5e cabling is the minimum performance category recommended. The performance category utilized should match the transmission speed required at the installation site.
The minimal conductor gauge permitted to connect between the PSE or power injector and the PD shall be 26 AWG (0.13 mm² ) for patch cords; 24 AWG (0.21 mm² ) for horizontal or riser cable.
UL 294 Statement Compliance with IEEE 802.3 specifications was not verified as part of UL 294.
The equipment is intended to comply with the section of the National Electrical Code, ANSI/NFPA 70, Article 725.121, Power Sources for Class 2 and Class 3 Circuits.
CAN/ULC-60839-11-1 Grade Grade assignment: I
Certifications CE, FCC, IC, UL 294, CAN/ULC-60839-11-1
Document number, and issue date and/or revision level EAH-8, Ver 01

Software

Management Application Access
Software Information The software version can be checked at <a href="https://unifi.ui.com/" target="_blank" rel="noopener noreferrer">https://unifi.ui.com</a>